APC NetShelter Rack PDU Advanced, Switched, 17.3kW, 3PH, 415V, 30A, 530P6, 48 Outlet
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 48 outlets in a 2.2" wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
AC input frequency50 - 60 Hz
AC outlet typesC13 coupler,C15 coupler,C19 coupler,C21 coupler
AC outlets quantity24 AC outlet(s)
CertificationCE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1
Daisy chainY
Depth75 mm
DisplayLCD
Height1780 mm
Load capacity17300 VA
Maximum current24 A
Maximum input current per phase30 A
Maximum total current draw per phase24 A
Mountingvertical
Nominal input voltage240V V
Nominal output voltage240 V
Non-operating altitude0 - 15240 m
On/off switchN
Operating altitude0 - 3048 m
Operating relative humidity (H-H)5 - 95 %
Operating temperature (T-T)-5 - 60 °C
Package depth132 mm
Package height1980 mm
Package weight12600 g
Package width262 mm
PDU typesSwitched
Power plugIEC 60309
Rack capacity0U
Storage relative humidity (H-H)5 - 95 %
Storage temperature (T-T)-25 - 65 °C
TypeThree-phase
Weight9600 g
Width56 mm

APC APDU10350SW

50/60 Hz, 200 - 240, 346 - 415VAC, Load Capacity 17300VA

apdu10350sw

In Stock

£2,740.32
£2,283.60 Ex VAT.